Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

LSOH Screened Torsion Resistant Loop Cable 0.6/1kV

Windmill Cables

Application

These cables are designed for special application condition in wind turbines, special for medium mechanical

stress and for operation under permanent influence of seawater and usage outdoor.

Standards

IEC 60502

EN 50363

HD 22.13

Construction

Conductor: Stranded bare copper conductor.

Insulation: Extruded halogen free rubber compound EI8.

Screen: Tinned wire copper braid.

Sheath: Extruded halogen free EVA compound EM8.

Technical Data

Rated Voltage Uo/U (Um):0.6/1 kV

Operating Temperatures:flexing: -35℃~+90℃; fixed installation: -40℃~+90℃

Minimum Bending Radii:fixed: 4×OD; flexing: 6×OD

Torsion Application:± 100 °/m

Maximum Permissible Tensile Load:15 N/mm² (in operation)

Short-circuit Temperature:250℃

Flame Retardant:EN 50265-2-1

Halogen Free:IEC 60754

Smoke Density:IEC 61034

Oil Resistant:Yes

Ozone Resistant:Yes

Silicone Free:Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
25×0.75 18.0 500
25×1 20.0 550
4×1.5 10.0 150
12×1.5 16.0 400
32×1.5 26.0 950
42×1.5 35.0 1700
12×2.5 23.0 620
5×2.5 15.0 300
4×4 13.5 300